Page 20 - HIOKI 2017 Field Measuring Instruments
P. 20
Clamp meters20 LEAKAGE CURRENT
CLAMP ON LEAK HiTESTER 3293-50 Easily read measured values from all
heights with the adjustable display
Slim core opens
wide for easier
clamping
• Innovative flip clamp design AC
• Flip display to see measurement
readings from any angle
• 1mA to 1000A accuracy guaranteed, 6 ranges 1000A
Powers on when you Innovative concept and bar graph display
open the clamp • Backlight (white LED)
"Flip" clamp Order Code: 3293-50 φ24mm
Displayed values automatically 3293-50
invert when flipped open!
φ40mm
φ24mm Bright white LEDs backlight
3283
True RMS Accessories 3283-20
1mA to 1000A Strap
Coin type lithium φ46mm
battery (CR2032)
Instruction manual CM3286
CARRYING CASE 9757
CLAMP ON LEAK HiTESTER 3283
3283-20 Easily monitor leak current fluctuations 3283 3283-20
9399 OUTPUT CORD Easily monitor leak current fluctuations
L9095 (BNC)
φ40mm • Measure leak current using highly sensitive 10μA
resolution (at 10.00 mA range)
True RMS • Indicate 50/60 Hz leak current components with the
1mA to 200A filtering function
• Monitor leak current conditions in combination with a
Memory HiCorder (monitor output, Model 3283 only)
• 3283-20: EN 61010-2-032:2012 Type A
to measure uninsulated hazardous live
conductors such as busbars AC 100/
3283 only MEMORY HiCORDER
200A 1000Hz
Order Code: 3283 (with analog / waveform monitor output, Not CE marked)
3283-20 (without analog / waveform monitor output)
Accessories Options OUTPUT CORD OUTPUT CORD AC ADAPTER 9445-02
CARRYING CASE 9399 OUTPUT CORD L9095 (Connect to L9096 (Connect to For USA, 9V/ 1A
Hand strap, Instruction manual L9094 (Connect to BNC terminal,1.5 m terminal block, 1.5 m AC ADAPTER 9445-03
3283: Stacked manganese battery (6F22) Banana terminal, (4.92 ft) length) (4.92 ft) length) For EU, 9V/ 1A
3283-20: Alkaline battery (6LR61) 1.5 m (4.92 ft) length)
■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
*Representative figures are provided for basic accuracy. For more detailed information, please refer to the individual product catalogs.
Model 3283 3283-20 3293-50
AC measurement system True RMS True RMS
Display refresh rate 1.1 sec. or less
Display backlight function 4 times/s (at FAST), 2 time/s (at NORMAL), 1 times/3 s (at SLOW)
Core jaw diameter 4
Safety standard category N/A
Max. rated voltage to earth φ 24 mm (0.94 in)
Crest factor φ 40 mm (1.57 in) CAT III 300 V
AC current 300 Vrms
(Frequency characteristics) CAT III 300 V
Basic accuracy 2.8 or less (1.68 or less at 1000 A range)
Frequency 300Vrms (insulated conductor) 300Vrms 30.00 m/ 300.0 m/ 6.000/ 60.00/ 600.0/ 1000 A
Basic accuracy
Auto power off 2.5 or less (1.5 at 200 A range) (45 to 400 Hz)
50/60 Hz, filter ON: ±1.5 %rdg.± 5 dgt.
10.00 m/ 100.0 m/ 1.000/ 10.00/ 200.0 A
(40 Hz to 2 kHz) N/A
--
45-66 Hz: ±1.0 %rdg.± 5 dgt.
4
100.0/ 1000 Hz (auto)
±0.3 %rdg.± 1 dgt.
4
Data hold 4 4
Maximum/ minimum/ average 4 Max value display (displays the maximum measured
value record function values reached since the power has been turned on)
Low pass filter ON/OFF 4 (fc=180 Hz) 4 (fc=180 Hz)
Other functions Output N/A Liquid crystal display (LCD) reversal
Dustproof and waterproof REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 N/A
A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200
A range), 5 Hz to 15 kHz frequency bandwidth (-3 dB)
IP40 (EN60529)
Power supply Stacked manganese battery (6F22) ×1, or AC Alkaline battery (6LR61) ×1 or, Coin type lithium battery CR2032×1
18 hours
adapter 9445-02 /-03 Stacked manganese battery (6F22) ×1
Continuous operating time 40 hours 40 hours
Dimensions and mass 62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 400 g (14.1 oz) 50 mm (1.97 in) W × 130 mm (5.12 in) H × 26 mm (1.02 in) D,
135 g (4.8 oz)