Page 15 - HIOKI 2017 Field Measuring Instruments
P. 15
DT4200 SERIES 15
DIGITAL MULTIMETER DIGITAL MULTIMETER DMM, Testers
DT4252, DT4253, DT4254, DT4255, DT4256 DT4281, DT4282
Standard models High-end models
Introducing a line of field-optimized Featuring high accuracy, extensive
instruments that can be chosen based additional functionality, and a broad
on the application at hand range of measurement parameters
• Standard DMM that Delivers Top Safety and • World's Premier Digital Multimeter
Reliability • Superior Accuracy and High Response
• Topped with Safety Terminal Shutters
• High-speed 0.9 s response for AC voltage
measurement A range: Only the A and
COM terminal inlets open
DT4255: Use as a replacement for the
Digital HiTester 3255-50 (discontinued).
Sleeve attached DT4254/55/56 Sleeve attached
Order Code: DT4252 (For laboratory and research use) Order Code: DT4281 (For electrical work in the field)
DT4253 (For instrumentation 4-20mA) DT4282 (For laboratory and research use)
DT4254 (Voltage measurement only model)
DT4255 (For electrical work in the field)
DT4256 (Multifunction model)
Model (DT42 ) 52 53 54 55 56 Model (DT42 ) 81 82
Features Features
CAT III 1000V, CAT IV 600V 44444 Safety CAT III 1000V, CAT IV 600V 44
Safety No current terminals (to prevent short-circuits) N/A N/A 4 4 N/A Includes terminal shutter mechanism for accident prevention 4 4
Voltage measurement function only N/A N/A 4 N/A N/A 60000 count, 5-digit display, high-resolution measurements 4 4
Voltage measurement terminals with current-limiting resistor and fast-blow fuse N/A N/A N/A 4 N/A Measurement ±0.025% DC V basic accuracy 44
Measurement Others High-speed 0.9 s response for AC voltage measurement 4 4 4 4 4 Wide 20 Hz to 100 kHz AC V frequency characteristics 44
AC/DC voltage automatic detection N/A 4 4 4 4 Low-pass filter cuts high harmonics 44
1700 V DC measurement (for measuring solar panel open-circuit voltage) N/A N/A 4 N/A N/A DC+ACV measurement, simultaneous DCV and ACV measurement 4 4
High-precision mV measurement at ±0.2% rdg. 4 N/A N/A N/A N/A Peak measurement 44
Very low current (μA/mA)/ Temperature measurement N/A 4 N/A N/A N/A Decibel conversion measurement 44
USB communications function supports PC measurements (optional) 4 4 4 4 4 USB communications function supports PC measurements (optional) 4 4
Dual display lets you check voltage and frequency simultaneously/ Backlight 4 4 4 4 4 Others Dual display lets you check voltage and frequency simultaneously 4 4
Broad -25°C (-13°F) to 65°C (149°F) operating temperature range N/A N/A 4 4 4 Back light, excessively high input with a red screen backlight 4 4
Specifications (Function/ Range)
Broad -15 (5°F) to 55°C (131°F) operating temperature range 4 4
DC Voltage 600.0mV - 1000V 4 4 4 4 4 Specifications (Function/ Range/ Basic accuracy)
1700V N/A N/A 4 N/A N/A DC Voltage 60.000mV - 1000.0V ±0.025%rdg.±2dgt. 4 4
*AC Voltage 60.000mV - 1000.0V ±0.2%rdg.±25dgt. 4 4
AC Voltage 6.000V - 1000V 4 4 4 4 4
AC/DC voltage automatic detection 600.0V N/A 4 4 4 4 *AC+DC Voltage 6.0000V - 1000.0V ±0.3%rdg.±30dgt. 4 4
DC Current 60.00μA - 60.00mA N/A 4 N/A N/A N/A DC Current 600.00μA - 600.00mA ±0.05%rdg.±5dgt. 4 4
60.00mA - 600.0mA N/A N/A N/A N/A 4 6.0000A - 10.000A ±0.2%rdg.±5dgt. N/A 4
6.000A - 10.00A 4 N/A N/A N/A 4 *AC Current 600.00μA - 600.00mA ±0.6%rdg.±5dgt. 44
6.0000A - 10.000A ±0.8%rdg.±5dgt. N/A 4
AC Current 600.0mA N/A N/A N/A N/A 4
6.000A - 10.00A 4 N/A N/A N/A 4 *AC Current (Clamp sensor) 10.00A - 1000A ±0.6%rdg.±2dgt. 4 N/A
AC Current (Clamp sensor) 10.00A - 1000A N/A 4 N/A 4 4 Resistance 60.000Ω - 600.0MΩ ±0.03%rdg.±2dgt. 4 4
Resistance 600.0Ω - 60.00MΩ 4 4 N/A 4 4 Temperature (thermocouples) -40.0 ˚C - +800.0 ˚C ±0.5%rdg.±3 ˚C 44
Temperature (thermocouples) -40.0 ˚C - +400.0 ˚C N/A 4 N/A N/A N/A Capacitance 1.000nF - 100.0mF ±1.0%rdg.±5dgt. 4 4
Frequency 4 4
Capacitance 1.000uF - 10.00mF 4 4 N/A 4 4 Continuity check 99.999Hz-500.00kHz ±0.005%rdg.±3dgt. 4 4
Diode check 4 4
Frequency 99.99Hz - 99.99kHz 4 4 4 4 4 Conductance 600.0Ω ±0.5%rdg.±5dgt. N/A 4
Continuity check 600.0Ω 4 4 N/A 4 4 3.600V ±0.1%rdg.±5dgt.
Diode check 1.500V 4 4 N/A 4 4 600.00nS ±1.5%rdg.±10dgt.
Voltage detection Hi/Lo N/A N/A 4 4 4 *Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed
DT4911, L9207-10 options L4930, L4931 options Note: Switch test tips depending on your application
CONTACT PIN SET
L4933 TEST PIN SET L4938 ALLIGATOR CLIP BUS BAR MAGNETIC
SET L4935 CLIP SET ADAPTER SET
L4936 L4937
SMALL ALLIGATOR CONNECTION BREAKER PIN SET TEST PIN SET GRABBER CLIP EXTENSION
CLIP SET L4934 CABLE SET L4939 L4932 9243 CABLE SET
L4930 (1.2m) L4931 (1.5 m)
CARRYING
DT4281, DT4253, DT4255, DT4256 options Options CASE C0201 CARRYING
CARRYING CASE (DT4250s only) CASE 3853
CLAMP ON PROBE CLAMP ON PROBE C0200 CARRYING CASE (DT4250s only)
9010-50 9132-50 (DT4220s only) C0202
(For DT4250s/ 80s)
CLAMP ON PROBE CONVERSION MAGNETIC STRAP MAGNETIC STRAP THERMOCOUPLES(K) COMMUNICATION
9018-50 ADAPTER 9704 Z5004 Z5020 DT4910 PACKAGE(USB)
(For DT4220s/ 50s) (Extra strength) -40 to 260 °C DT49 00-01
(-40 to 500 °F) (OS: Windows8.1/8/7)
Note: Use with the conversion adapter 9704, required for connecting clamp on probes
Note: When measuring in a CAT IV or CAT III environment, be sure to attach the sleeve to the test leads.