Page 14 - HIOKI 2017 Field Measuring Instruments
P. 14
14 POCKET/HANDHELD
Safety Measurement Others
Test leads with sleeves DIGITAL MULTIMETER
DMM, Testers DT4221, DT4222, DT4223, DT4224
When measuring in a CAT IV or CAT III
environment, be sure to attach the sleeve Pocket models
to the test leads.
When the CAT (measurement category) Featuring a compact body for
rating of the main unit is lower than that of ergonomic hold and a reliable, safe
test leads, the CAT of the main unit takes design
precedence.
• CAT IV 300 V / CAT III 600 V safety in a
CARD HiTESTER 3244-60 compact footprint
• High-speed 0.9 s response for AC voltage
measurement
Sleeve attached Sleeve attached
Compact, palm-sized body Order Code: DT4221 (For electrical work in the field)
less than 1cm thin DT4222 (For multiple applications)
DT4223 (For electrical work in the field)
AC/DC 42MΩ DT4224 (For multiple applications)
500V Continuity check
Order Code: 3244-60
Accessories Model (DT42 ) 21 NEW NEW
15 mm CARRYING 22 23 24
Features 4
CASE C0204 444
CAT III 600V, CAT IV 300V N/A
Sleeves N/A 4 4
World's First! Unintentional voltage input 4
Cable length: Extra length for reaching Instruction manual protection, circuit breaker false trip prevention 4 444
46 cm (17.7 in) inside sockets Coin type litium High-speed 0.9 s response for AC voltage measurement 4 N/A 4 N/A
battery (CR2032) N/A 444
AC/DC voltage automatic detection N/A N/A 4 4
N/A 4 4
Note: When measuring in a CAT III environment, be sure to attach the sleeve to the test leads. Backlight display 4
4 444
Overinput warning via red backlight 4 444
N/A N/A 4 N/A
SOLAR HiTESTER 3245-60 Broad -10 (14°F) to 65°C (149°F) operating temperature range N/A 444
4 4 N/A 4
Specifications (Function/ Range) 4 444
N/A 444
Sleeve attached DC Voltage 600.0mV - 600.0V 4 4 N/A 4
N/A 4 N/A
Environmentally-friendly AC Voltage 6.000V - 600.0V
DMM
AC/DC voltage automatic detection 600.0V
AC/DC 42MΩ Resistance 600.0Ω - 60.00MΩ
600V Continuity check
Capacitance 1.000uF - 10.00mF
Order Code: 3245-60
Cable length: Frequency 99.99Hz - 9.999kHz
52 cm (20.4 in)
Continuity check 600.0Ω
Diode check 1.500V
Accessories Voltage detection Hi/Lo
New DT4223/DT4224 Digital Multimeters with resistance measurement capability
Built-in unintentional voltage input protection
Sleeves World's First! and circuit breaker false trip prevention
Instruction manual
Coin type litium Featuring robust protection in case voltage is unintentionally input
battery (CR2032) during resistance, continuity, capacitance, or diode measurement
Note: When measuring in a CAT IV or CAT III environment, be sure to attach the sleeve to the test leads.
Prevent potential accidents during incorrect input
PENCIL HiTESTER 3246-60
The measurement circuit switches only after detecting
Sleeve attached the appropriate signal. This way, even if you mistakenly
input voltage, accidents due to tripped breakers or arcs
Pencil-type DMM with LED light AC/DC 42MΩ will not happen.
600V Continuity check LoZ icon identifies switched measurement circuit
When the instrument detects resistance, continuity,
capacitance, or diode input, the LoZ icon is shown on
the display, allowing you to identify at a glance which
measurement circuit has been selected.
Warning function notifies you of incorrect input
The instrument’s display flashes red to warn you when
voltage has been mistakenly input while the instrument is
set to the resistance range.
Backlight LED LED light
Accessories
Pocket models Standard models High-end models
3246-70 DT4221 to 4224 accessories DT4252 to 4256 accessories DT4281 to 4282 accessories
Skeleton model (blue)
TEST LEAD DT4911 TEST LEAD L9207-10 TEST LEAD L9207-10
54 cm (1.77ft) length 90 cm (2.95 ft) length 90 cm (2.95 ft) length
Cable length: 80 cm (31.5 in) Test lead fits neatly into back Sleeves
of instrument Instruction manual
Order Code: 3246-60 Coin type litium
battery (CR2032) Instruction manual Instruction manual Instruction manual
LR03 alkaline battery ×1 LR03 alkaline battery ×4 LR6 alkaline battery ×4
Holster
Note: When measuring in a CAT IV or CAT III environment, Holster
be sure to attach the sleeve to the test leads.