Page 14 - HIOKI 2017 Field Measuring Instruments
P. 14

14 POCKET/HANDHELD
                                                                                                                                                Safety Measurement Others
                     Test leads with sleeves                                                                                                                                       DIGITAL MULTIMETER
DMM, Testers                                                                                                                                                               DT4221, DT4222, DT4223, DT4224
When measuring in a CAT IV or CAT III
environment, be sure to attach the sleeve                                                                                                                                                Pocket models
to the test leads.
When the CAT (measurement category)                                                                                                                                                                   Featuring a compact body for
rating of the main unit is lower than that of                                                                                                                                                         ergonomic hold and a reliable, safe
test leads, the CAT of the main unit takes                                                                                                                                                            design
precedence.
                                                                                                                                                                                                              • CAT IV 300 V / CAT III 600 V safety in a
CARD HiTESTER 3244-60                                                                                                                                                                                           compact footprint

                                                                                                                                                                                                              • High-speed 0.9 s response for AC voltage
                                                                                                                                                                                                                measurement

                                                                         Sleeve attached                                                                                                                       Sleeve attached

                                    Compact, palm-sized body                                                                                                               Order Code: DT4221 (For electrical work in the field)
                                    less than 1cm thin                                                                                                                     	 DT4222 (For multiple applications)
                                                                                                                                                                           	 DT4223 (For electrical work in the field)
                                          AC/DC 42MΩ                                                                                                                       	 DT4224 (For multiple applications)
                                           500V Continuity check

                                    Order Code: 3244-60

                                               Accessories                                                                   Model (DT42 )                                                                                               21         NEW NEW
                                    15 mm CARRYING                                                                                                                                                                                            22 23 24
                                                                                                                             Features                                                                                                     4
                                                CASE C0204                                                                                                                                                                                     444
                                                                                                                                                                           CAT III 600V, CAT IV 300V                                     N/A
                                                               Sleeves                                                                                                                                                                        N/A 4 4
                                                                                                                                                                           World's First! Unintentional voltage input                     4
Cable length:                       Extra length for reaching  Instruction manual                                                                                          protection, circuit breaker false trip prevention              4    444
46 cm (17.7 in)                     inside sockets             Coin type litium                                                                                            High-speed 0.9 s response for AC voltage measurement           4   N/A 4 N/A
                                                               battery (CR2032)                                                                                                                                                          N/A   444
                                                                                                                                                                           AC/DC voltage automatic detection                             N/A  N/A 4 4
                                                                                                                                                                                                                                              N/A 4 4
                 Note: When measuring in a CAT III environment, be sure to attach the sleeve to the test leads.                                                            Backlight display                                              4
                                                                                                                                                                                                                                          4    444
                                                                                                                                                                           Overinput warning via red backlight                            4    444
                                                                                                                                                                                                                                         N/A  N/A 4 N/A
SOLAR HiTESTER 3245-60                                                                                                                                                     Broad -10 (14°F) to 65°C (149°F) operating temperature range  N/A   444
                                                                                                                                                                                                                                          4    4 N/A 4
                                                                                                                             Specifications (Function/ Range)                                                                             4    444
                                                                                                                                                                                                                                         N/A   444
                                                           Sleeve attached                                                   DC Voltage                                                       600.0mV - 600.0V                            4    4 N/A 4
                                                                                                                                                                                                                                              N/A 4 N/A
                                    Environmentally-friendly                                                                 AC Voltage                                                       6.000V - 600.0V
                                    DMM
                                                                                                                             AC/DC voltage automatic detection 600.0V

                                          AC/DC 42MΩ                                                                         Resistance                                                       600.0Ω - 60.00MΩ
                                           600V Continuity check
                                                                                                                             Capacitance                                                      1.000uF - 10.00mF
                                    Order Code: 3245-60
                 Cable length:                                                                                               Frequency                                                        99.99Hz - 9.999kHz
                 52 cm (20.4 in)
                                                                                                                             Continuity check                                                 600.0Ω

                                                                                                                             Diode check                                                      1.500V

                                                               Accessories                                                   Voltage detection                                                Hi/Lo

                                                                                                                             New DT4223/DT4224 Digital Multimeters with resistance measurement capability
                                                                                                                                                                           Built-in unintentional voltage input protection
                                                                                              Sleeves                        World's First!                                     and circuit breaker false trip prevention
                                                                                               Instruction manual
                                                                                               Coin type litium              Featuring robust protection in case voltage is unintentionally input
                                                                                               battery (CR2032)              during resistance, continuity, capacitance, or diode measurement
           Note: When measuring in a CAT IV or CAT III environment, be sure to attach the sleeve to the test leads.
                                                                                                                                                                                              Prevent potential accidents during incorrect input
 PENCIL HiTESTER 3246-60
                                                                                                                                                                                              The measurement circuit switches only after detecting
                                                                                                            Sleeve attached                                                                   the appropriate signal.  This way, even if you mistakenly
                                                                                                                                                                                              input voltage, accidents due to tripped breakers or arcs
Pencil-type DMM with LED light AC/DC 42MΩ                                                                                                                                                     will not happen.

                                                                  600V Continuity check                                                                                                       LoZ icon identifies switched measurement circuit

                                                                                                                                                                                              When the instrument detects resistance, continuity,
                                                                                                                                                                                              capacitance, or diode input, the LoZ icon is shown on
                                                                                                                                                                                              the display, allowing you to identify at a glance which
                                                                                                                                                                                              measurement circuit has been selected.

                                                                                                                                                                                              Warning function notifies you of incorrect input
                                                                                                                                                                                              The instrument’s display flashes red to warn you when
                                                                                                                                                                                              voltage has been mistakenly input while the instrument is
                                                                                                                                                                                              set to the resistance range.

                                    Backlight LED              LED light
                                                                         Accessories
                                                                                                                                                                           Pocket models      Standard models                            High-end models

                                           3246-70                                                                           DT4221 to 4224 accessories DT4252 to 4256 accessories DT4281 to 4282 accessories
                                    Skeleton model (blue)
                                                                                                                             TEST LEAD DT4911                                                 TEST LEAD L9207-10                         TEST LEAD L9207-10
                                                                                                                             54 cm (1.77ft) length                                            90 cm (2.95 ft) length                     90 cm (2.95 ft) length

     Cable length: 80 cm (31.5 in)  Test lead fits neatly into back  Sleeves
                                    of instrument                    Instruction manual
Order Code: 3246-60                                                  Coin type litium
                                                                     battery (CR2032)                                        Instruction manual                                               Instruction manual                         Instruction manual
                                                                                                                             LR03 alkaline battery ×1                                         LR03 alkaline battery ×4                   LR6 alkaline battery ×4
                                                                                                                                                                                              Holster
                                    Note: When measuring in a CAT IV or CAT III environment,                                 Holster
                                                        be sure to attach the sleeve to the test leads.
   9   10   11   12   13   14   15   16   17   18   19