Page 11 - HIOKI 2017 Field Measuring Instruments
P. 11
ANALOG/SAFETY 11 DMM, Testers
HiTESTER 3030-10
■ Basic specifications Sleeve attached
Basic Analog Tester (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
(20kΩ/V)
DC voltage 0 to 0.3/3/12/30/120/300/600 V
Accuracy ±2.5 % of f.s. reading
New insulated test AC/DC DC 3MΩ Measurement range AC voltage 0 to 12/30/120/300/600 V
pin sleeves prevents 600V 300mA Accuracy ±2.5 % of f.s. reading (12V: ±4 %)
short-circuits DC current 0 to 60 μA/30/300 mA
Order Code: 3030-10 Accuracy ±3 % of f.s. reading
Accessories Resistance 0 to 3kΩ, R×1/×10/×100/×1k
TEST LEAD Spare fuse Options Accuracy ±3 % of scale length
L9207-30 R6P manganese HIGH-VOLTAGE
CARRYING battery×2 PROBE 9017 Short circuit protection of power line by fuse*
CASE (Not CE marked) Protective system (up to 250 VAC commercial power input),
9390
Overload protection of meter device by diode
Instruction Functions Battery check
manual
Functions Drop proof 4
Note: When measuring in a CAT III environment, be sure to attach the sleeve to the test leads. Power supply For resistance measurement range, R6P (AA)
Note: With cap removed, operates as a CAT II device. For more information, please see p.13. Dimensions and manganese battery× 2
mass
Note: The temperature scale on Model 3030-10 is not effective without Model 9021-01 95 mm (3.74 in) W × 141 mm (5.55 in) H × 39
temperature probe, which has been discontinued. mm (1.54 in) D, 280 g (9.9 oz)
*Note: This system is not for protecting the instrument from damage but for securing safety.
MULTI TESTER 3008 Suitable for use on industrial
power lines (20kΩ/V)
■ Basic specifications
Drop-proof (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
& simple dust-proof
AC/DC 1MΩ DC voltage 0 to 6/30/60/300/600 V
design 600V
Accuracy ±2.5 % of f.s. reading
Measurement range Functions
• High-power fuse protects up to 50000 A AC voltage 0 to 6/30/150/300/600 V
• Supply current limiting resistance of Accuracy ±2.5 % of f.s. reading
Resistance 0 to 10kΩ, R×1/×10/×100
10-ohm restricts short circuit current Accuracy ±3 % of scale length
Order Code: 3008
Circuit: Fuse-protected, internal circuit
Accessories *The 9060 has a shortened Protective system protection using the 10Ω resistance
metal tip for safety reasons.
Meter: Diode-protected
Drop proof 4
TEST LEAD 9060 Carring case Power supply For resistance measurement range, R6P (AA)
Spare fuse Dimensions and manganese battery× 2
Manganese battery (R6P) ×2 mass
Instruction manual 94 mm (3.7 in) W × 134 mm (5.28 in) H × 56
mm (2.2 in) D, 350 g (12.3 oz)
SAFETY HiTESTER 3258
Voltage measurement Also safe for metallic conductors
safety assured by non-
contact testing
• Capture the voltage value of
covered electric wires
AC
600V
Order Code: 3258 Reliably safe, non- Easily measure right through
metallic resin heads cable insulation
■ AC voltage measurement accuracy (on insulated PVC cables or equivalent, 100 mm2 or thicker)
Accessories
Ranges Range of Display Display Accuracy Soft carrying case
LR6 alkaline
(auto- ranging) guaranteed accuracy range resolution 40 to 60Hz 66 to 400Hz battery ×6 Measurement Principle
Instruction manual
420.0 V 30.0 to 420.0 V 0.0 to 420.0 V 0.1 V ±1.5% rdg.±5 dgt. ±2.5% rdg.±5 dgt.
600 V 380 to 480 V 380 to 600 V 1 V ±2.0% rdg.±5 dgt. −
481 to 600 V ±5.0% rdg.±5 dgt.
■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Measurement parameter AC voltage (AC potential bridge)
Objects of Insulated conductors (IV or CV equivalent, min. 100 mm² x-section), metal conductors
measurement
Note: Not usable on shielded conductors
Max. rated voltage to earth 600 VAC rms
Temperature characteristics 0.05% rdg./ °C
Influence of conductor 0.5% rdg. IV orCV equivalent insulated conductors (combine with above accuracy Measurements with traditional non-metallic-contact
diameter voltmeters and phase detectors depend on the coupling
if diameter is 38 mm² to 100 mm²) capacitance (C1 and C2) between voltage detector electrodes
in the probe tips and the measurement objects. That
Influence of adjacent wiring ±5% rdg. or less voltage detection method can present problems due to the
dependence of the coupling capacitance on the material
Influence of external None properties of the measurement objects, making accurate
magnetic field voltage determination (Vm = Vm2 - Vm1) problematic.
The SAFETY HiTESTER 3258 employs a new technological
Display refresh rate Approx. once every 0.6 seconds principle to detect accurate measurement voltage (Vm)
independent of coupling capacitance.
Display response 2.4 s or less
Functions Data hold function, Auto power off, Low battery warning
Power supply LR6(AA) alkaline battery ×6, Continuous operating time: 14 h (Power ON, no measurement)
Dimensions and mass 51 mm (2.01 in) W × 275 mm (10.83 in) H × 37.5 mm (1.48 in) D (one probe),
670 g (23.6 oz)